París-García, FedericoBarroso, AlbertoParis, Federico2024-02-092024-02-092018-03-14Paris-Garcia F, Barroso A, Paris F. A study of the reproducibility and reliability of the musculo-articular stiffness of the ankle joint. J Mech Behav Biomed Mater. 2018 Jun;82:145-153. doi: 10.1016/j.jmbbm.2018.03.017. Epub 2018 Mar 17. PMID: 29601986.10.1016/j.jmbbm.2018.03.017https://hdl.handle.net/10433/20016El objetivo de este trabajo fue evaluar la reproducibilidad, fiabilidad y utilidad de la rigidez musculoarticular (MAS) de la articulación del tobillo, midiéndola mediante la técnica de vibración libre. Para este análisis se diseñó y realizó un protocolo test-retest el mismo día para determinar la reproducibilidad a corto plazo de f, k y ku. Se obtuvo la reproducibilidad a corto plazo de ky ku en 1 día en términos absolutos y reproducibilidad relativa (Coeficiente de correlación intraclase (ICC) para ambos pies. Se analizó la fiabilidad de k y ku en términos absolutos y en términos relativos (basándose en la repetición del protocolo durante 1 semana para ambos pies. También se analizó la utilidad para todas las variables (durante 1 día y 1 semana) El análisis estadístico realizado mostró la alta reproducibilidad, fiabilidad y utilidad de la prueba MAS, que fue más consistente con ku que con k. Por tanto, la rigidez unitaria (ku) demostró ser representativa de la respuesta mecánica de la articulación del tobillo obtenida mediante técnicas de vibración libre, lo que permite la comparación entre diferentes sujetos. Los resultados obtenidos de este estudio permitiran desarrallar futuras invesigaciones donde se analize la influencia de otros paramatros tales como la fatiga, el entrenamiento, el efecto de tratamiento ortopodológicos,... sobre la rigidez musculo-articular medida con este procedimiento de laboratorio.The objective of this work was to evaluate the reproducibility, reliability and usefulness of the musculo-articular stiffness (MAS) of the ankle joint, measuring it by the free vibration technique. Seventeen (nine males and eight females) healthy university students were included in the study. Force (f), MAS (k) and unitary MAS (ku) (defined as the ratio between the value of stiffness k obtained in the test (absolute terms) and the value of force (f)) were obtained. A test retest protocol was designed and performed on the same day to determine the short-term reproducibility of f, k and ku. Short-term reproducibility of k and ku on 1 day in absolute terms (< 7% Coefficient of Variation (CV)) and relative reproducibility (Intraclass Correlation Coefficient (ICC) and Pearson ≥0.97) for both feet were obtained. The reliability of k and ku in absolute terms (< 9% CV) and in relative terms (ICC and Pearson≥0.93) based on repeating the protocol for 1 week was analysed for both feet. To analyse the usefulness, the Effect Size (ES) ratio=“Trivial” for all variables (for 1 day and 1 week) and the Smallest Worthwhile Change (SWC) ratio (Typical Error (TE)<SWC) = “GOOD” for k and ku (1 day and 1 week) were considered. The Minimal Difference needed to be considered “real” (MD) for ku ≅ 3.5% (1 day); ku≅ 8.5% (1 week) (p <0.05) was obtained. The statistical analysis carried out displayed the high reproducibility, reliability and usefulness of the MAS test, which was more consistent with ku than k. Therefore, the unitary stiffness (ku) proven to be representative of the mechanical response of the ankle joint obtained by free vibration techniques, which allows comparison between different subjects.application/pdfenStiffnessFunctional responseFree vibration techniqueReliabilityA study of the reproducibility and reliability of the musculo-articular stiffness of the ankle jointEstudio de reproducibilidad y fiabilidad de la rigidez Musculo-articular de la articulación del tobillojournal articlerestricted access