Publication:
Validity and reliability of Omegawave® device to measure RR intervals at rest

dc.contributor.authorNaranjo Orellana, José
dc.contributor.authorRuso Álvarez, José Francisco
dc.contributor.authorRojo Álvarez, José Luis
dc.date.accessioned2019-09-04T08:22:03Z
dc.date.available2019-09-04T08:22:03Z
dc.date.issued2019
dc.description.abstractObjective The aim of this study was to validate the measurements of the RR intervals taken at rest by the Omegawave® device (OWD) by comparing them to the measurements simultaneously made by an ECG, considered to be our gold standard. Methods Five rest measurements were made for 10 minutes on five different days to 10 men and three women participated in this study (24.8 ± 5.05 years; 71.82 ± 11.02 kg; 174.35 ± 9.13 cm). RR intervals were simultaneously recorded using OWD and ECG The processing of ECG signals (digitised at 43 samples per second) included the detrending of baseline noise and a high-pass filtering for emphasizing the QRS complexes and attenuating the T waves, often prominent in sport populations. After obtaining the gold-standard beat times from the ECG, the beat times from the OWD were automatically aligned to them and compared to check whether both measurements could be considered superimposable. A Bland-Altman analysis was applied to the complete time series of each subject and it was repeated for the five measurements made for all subjects. Results The results suggest that the RR interval measurements performed by the OWD have very strong agreement with those made with an ECG. Deviations not exceeding 25 ms could be expected in 95% of the cases and this is within manageable ranges both for clinical practice and sports. Conclusions To conclude, RR intervals measured by the OWD can be considered highly consistent with those obtained from the gold standard (ECG).es_ES
dc.description.sponsorshipUniversidad Rey Juan Carloses_ES
dc.description.versionPreprintes_ES
dc.identifier.doi10.46661/rio.6698
dc.identifier.urihttp://hdl.handle.net/10433/6698
dc.language.isoenes_ES
dc.publication.year2019
dc.publisherUniversidad Pablo de Olavidees_ES
dc.rightsAtribución-NoComercial 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectHeart rate variabilityes_ES
dc.subjectRR intervalses_ES
dc.titleValidity and reliability of Omegawave® device to measure RR intervals at restes_ES
dc.typeinfo:eu-repo/semantics/datasetes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationc6b04c97-6b9b-4cd9-9533-3047d72bf453
relation.isAuthorOfPublication.latestForDiscoveryc6b04c97-6b9b-4cd9-9533-3047d72bf453

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
OWD.zip
Size:
62.69 KB
Format:
Unknown data format
Description:
Data from Omegawave device
Loading...
Thumbnail Image
Name:
ECG.zip
Size:
13.87 MB
Format:
Unknown data format
Description:
Data from ECG device

Collections